Sensors
Esta página aún no está disponible en español. Se muestra la versión en inglés.
The Sensors tab lists every sensor connected to the device, along with its current value and last update time.

If the sensors are connected via a Sensorbee tag, the tag metadata is also shown — serial, family type, preheat, version, and production year.

This tab also exposes configuration settings for particle and gas sensors, when present.
Particle sensor settings

| Setting | Description |
|---|---|
| Always On | Keep the particle sensor running continuously so it can be read more often. Increases power consumption — recommended only with external power. |
| Average | Number of samples collected and averaged before updating the reported value. Higher values increase sampling time. |
| Fan Cleaning Interval | Interval (in seconds) between fan cleaning cycles. |
| Offset Constant | Offset constant applied to the particle mass values. |
| Offset Factor | Offset factor applied to the particle mass values. |
| Sampling Time | How long the sensor takes to collect a single sample. |
Gas sensor settings

| Setting | Description |
|---|---|
| Always On | Keep the gas sensor running continuously. Increases power consumption — recommended only with external power. |
| Offset Constant | Offset constant applied to the gas sensor output. |
| Offset Factor | Offset factor applied to the gas sensor output. |
| Sensitivity | Sensitivity factor in nA per ppm. |
| Temperature Compensation | Enables or disables temperature compensation. |
| Zero Current Offset | Zero current offset in nA. |
For the underlying calculations, see Gas Sensor Calculations.