Sensorbee Pro2 Cellular
Datasheet for the Sensorbee Pro2 Cellular monitoring station.
Download PDF
Specifications
These are the specifications of the base unit, as in the Product Manual revision 2.1. For gas modules, the noise module, external sensors and accessories, see the catalogue and the other datasheets.
General
| Parameter | Value |
|---|---|
| Model | SB8202, Sensorbee Pro2 |
| Type | Fixed-installation outdoor indicative environmental monitoring station |
| Dimensions (H × W × D) | 145 × 200 × 80 mm (5.7 × 7.9 × 3.1 in) |
| Weight | 1.9 kg (4.2 lb) |
| Enclosure | Polyamide, sealed, for permanent outdoor installation |
| Mounting | Bracket for pole or wall (supplied), two stainless steel hose clamps for pole mounting (supplied) |
| Operating temperature | −20 to +60 °C (−4 to +140 °F) |
| Operating humidity | 0 to 99 %RH, non-condensing |
| Reporting interval | 5 minutes as delivered, adjustable |
| Local data memory | About 7 days of measurements |
Standard measurement modules
| Parameter | Value |
|---|---|
| Particulate matter module, SB4102 | |
| Principle | Optical particle counter, air flow 2.5 L/min, heated inlet active above 60 %RH |
| Particle size range | 0.3 to 10 µm, in five size bins |
| Mass concentration | PM1, PM2.5 and PM10, 0 to 1000 µg/m³, resolution 1 µg/m³ |
| Number concentration | 0 to 2600 particles per cm³ |
| Precision | ±5 % for PM1 and PM2.5, ±10 % for PM10 |
| Calibration | Each module is calibrated individually at three points and has its own calibration certificate |
| Certification | MCERTS for PM2.5 and PM10 as part of the Pro2 |
| EnviroSense module, SB4502 | |
| Air temperature | Accuracy ±0.2 °C from −20 to +50 °C |
| Relative humidity | 0 to 100 %RH. ±1.5 %RH from 0 to 95 %RH; ±1.0 %RH from 20 to 75 %RH at 15 to 55 °C |
| Barometric pressure | 300 to 1250 hPa, ±0.5 hPa |
Power
| Parameter | Value |
|---|---|
| Power input | 5–24 V DC, 2 A, at the M8 4-pin power connector |
| Power source | Limited-power DC source: Sensorbee solar panel, power adapter or external battery pack, or an equivalent approved supply |
| Internal battery | Rechargeable lithium-ion pack, 3.7 V, 20.3 Ah (75 Wh) |
| Replacement battery | SB4922, Pro2 Battery Pack |
Radio and communication
| Parameter | Value |
|---|---|
| Cellular technology | LTE-M (LTE Cat-M1) and NB-IoT (LTE Cat-NB1) |
| Bands, United States and Canada | LTE-M bands 2, 4, 12, 13 |
| Bands, Australia and New Zealand | LTE-M bands 3, 5, 28 |
| Bands, European Union and United Kingdom | LTE-M and NB-IoT bands 8, 20 |
| Maximum RF output power | +23 dBm (power class 3) |
| Typical receiver sensitivity | −108 dBm on LTE-M, −114 dBm on NB-IoT |
| Antenna | Internal. Not accessible to the user and not replaceable. |
| Radio module | Nordic Semiconductor nRF9160. Contains FCC ID: 2ANPO00NRF9160. Contains IC: 24529-NRF9160. |
| SIM | Nano-SIM. A SIM that works with many operators worldwide is installed. You can use your own SIM instead. |
| Data protocol | LwM2M version 1.1 or later, over DTLS with pre-shared key |
Interfaces
| Interface | Description |
|---|---|
| Power connector | M8, 4-pin male, type A |
| Sensor ports | M8, 6-pin female, type A, for Sensorbee external sensors. Up to four, depending on configuration. |
| Expansion connector | M12, 8-pin, Modbus RTU, with 5 V or 12 V sensor supply. Standard serial settings: 19200 bit/s, 8 data bits, even parity, 1 stop bit. Earlier units: 115200 bit/s. |
| Service port | USB-C, inside the enclosure. Serial terminal at 9600 bit/s, 8 data bits, no parity, 1 stop bit. |
| Internal bays | Six bays for gas modules, one bay for the noise module |
Specifications are subject to change without notice.