Configuration over USB-C
The Pro2 has a USB-C service port. You use it with a serial terminal program on a computer to change settings. The port is on the main board inside the enclosure, so you must open the enclosure to reach it; see Opening and closing the unit. Most installations never need it.
CAUTION. Open the enclosure only in a safe and dry place. Switch the unit off before you open the enclosure. Use ESD protection. Do not open the enclosure in rain or where water can get in.
Connecting
Connect a computer to the USB-C service port and open a serial terminal program. Sensorbee uses the program Tera Term; see the Tera Term installation guide. Set the connection to:
| Setting | Value |
|---|---|
| Baud rate | 9600 bit/s |
| Data bits | 8 |
| Parity | None |
| Stop bits | 1 |
When the unit has started, the main menu appears. If you see nothing, press Esc. In every submenu, Esc goes back one step without saving.
The unit does not work normally in menu mode. While the USB-C cable is connected, the status LED is steady white. The unit does not measure and report as usual. It connects to the mobile network only if you select Connect To Network in the modem menu. To put the unit back into service, remove the USB-C cable and restart the unit.
Main menu
Select a menu with the number shown next to it on the screen.
| Menu | Purpose |
|---|---|
| Polling interval | How often the unit measures and reports. |
| Firmware update | Load new firmware over USB-C. |
| System settings | Baud rate, parity and stop bits for the external sensors, and the sensor supply voltage. |
| Modbus settings | Address, baud rate and device name for units that have a Modbus RTU output. |
| Modem | Mobile network status, SIM details, APN and network selection. |
| Reset | Restarts the unit. Use it after you change a setting that needs a restart. It does not restore the factory settings. |
See also the main menu page with a screenshot of the terminal.