The Pro2 is made to be simple to install. This page shows the whole job in seven steps. The linked pages give the details.
Read Safety before you start. Work at height, electrical work and work on the battery are for qualified persons only.
Indoors, before you go to the site
- Unpack and check. Check that all parts are in the box and that nothing is damaged. See What is in the box.
- Install gas modules. Only if you ordered gas modules separately. See Installing or replacing gas modules.
- Connect power and switch on. Connect the power source. Hold the power button for 2 seconds. See Connecting power and sensors and Switching on for the first time.
- Pair the unit. Scan the QR code on the side label and follow the steps on the screen. See Connecting to a data platform.
- Check the data. Check on the data platform that every sensor sends values. See Commissioning.
On site
- Mount the unit. Switch off. Mount the unit upright, 3 to 4 m above the ground. See Switching off and Mounting.
- Switch on and confirm. Connect power and sensors. Switch on. Check that the unit is online.
Test indoors first. Do steps 1 to 5 indoors before you go to the site. It is much easier to find a problem on a table than on a pole.
Status LED at start
| LED | What it means |
|---|---|
| Blue, steady | The unit is connecting to the mobile network. |
| Purple, blinking | The unit is waiting to be paired (step 4). |
| Green, one blink, then off | The unit is online. The LED is off in normal operation. |
| Red | A fault, a low battery, or the unit is switching off. See Status LED. |
Good data starts with a good location. Free air flow around the air inlet. No chimneys, exhaust outlets or running engines nearby. Shade for the unit, sun for the solar panel, and a good mobile signal. See Choosing the location.